Hot-dip galvanized hex bolts, a nut and a washer
FASTENODE / Our Specialty

ISO-FitGalvanized Bolts

Undersized threads before galvanizing, standard metric fit after. Mainly 8.8U; 4.8U, 6.8U and 10.9U also available.

Standard NutsStandard Tapped HolesHot-Dip Zinc Protection
THREAD SYSTEMMetric
PROPERTY CLASSES4.8 · 6.8 · 8.8 · 10.9
SURFACE TREATMENTHot-dip galvanized
DESIGN INTENTStandard internal-thread fit

Standard Fit. Practical Advantages.

From assembly and maintenance to volume purchasing, ISO-fitting galvanized bolts work with your existing product design.

Keep Standard Nuts and Tapped Holes

The galvanized thread fits standard internal threads, avoiding enlarged holes and additional machining.

Assembly and Maintenance

For machined components and equipment that retain their existing tapped holes through assembly and servicing.

An Alternative to M6+ Stainless Steel Bolts

Retain existing holes and mounting geometry with a cost-saving alternative to stainless steel bolts.

Volume Purchasing for Established Designs

For equipment with finalized drawings and mounting details, reducing fastener purchasing costs while keeping the existing design.

Hot-Dip Zinc Protection

A hot-dip galvanized zinc layer protects the steel while retaining standard thread fit.

Outdoor Equipment

For outdoor enclosures and brackets, including transformer housings, electrical equipment and auxiliary wind equipment.

Undersized Bolt Threads
or Oversize Nut Threads?

A thick zinc layer needs room in the thread assembly. One route makes the external thread smaller before galvanizing; the other enlarges the mating nut’s internal thread to a specified tolerance.

01
Before GalvanizingExternal Thread Preparation
ISO-fitting approach, before coatingThe steel external thread lies below the reference profile to make room for the zinc layer.Room for ZincSteel BoltReference ProfileUndersized Before Coating
External ThreadUndersized · 6az
02
After Coating & AssemblyMatched Internal Thread
ISO-fitting approach, after coatingThe zinc layer fills the planned allowance on the external thread, which mates with a standard internal thread.Standard Internal ThreadContinuous Zinc LayerSteel Bolt
Mating Internal ThreadStandard · H / G
SteelZinc LayerReference Profile

Longitudinal Section · Coating and Clearance Exaggerated

The external thread is made undersize before galvanizing. This reserves room for zinc while keeping the specified standard internal thread in the mating part.

Conceptual comparison, not a dimensional drawing.

Defined Tolerances. Matched Threads.

Oversize-tapped nuts follow defined tolerance requirements under ISO 10684 and ISO 965-5. The allowance is specified, with thread dimensions, property classes and engagement length considered together.

The two routes place the allowance in different threads: 6az external threads before galvanizing pair with the specified H/G internal threads; conventional galvanized bolts pair with 6AZ/6AX oversize internal threads. Each combination forms a distinct mating system.

Technical Reading: Thread Engagement

ISO-Fit or Conventional HDG.
We Supply Both.

Alongside the ISO-fitting bolts introduced above, we also supply conventional hot-dip galvanized bolts with oversize-tapped nuts. Undersized-thread bolts pair with standard nuts; conventional galvanized bolts pair with oversize nuts. We supply both combinations to suit your project.

01 / Our Specialty

ISO-Fit Bolts + Standard Nuts

Undersized external threads reserve room for zinc before galvanizing. The coated bolt fits the specified standard nut or an existing standard metric tapped hole.

6az before coating → H / G internal thread

For equipment, existing tapped holes and suitable stainless-steel cost-reduction projects.

ISO 965-4 · ISO 10684Enquire About This Assembly
02 / Also Available

Conventional HDG Bolts + Oversize Nuts

Standard bolts are hot-dip galvanized and paired with nuts tapped to the specified oversize tolerance. The nut provides the zinc allowance. We supply the matched assembly.

g / h before coating → 6AZ / 6AX internal thread

For projects and volume orders using conventional hot-dip galvanized bolt-and-nut assemblies.

ISO 965-5 · ISO 10684Enquire About This Assembly

Bare Nut Threads.
Protected in Assembly.

A bare internal thread does not mean an unprotected joint. Tapping a nut after galvanizing exposes its steel thread. Once assembled with a hot-dip galvanized bolt, zinc on the bolt can provide electrochemical protection to the mating nut thread as well as the bolt itself.

The Assembly: Zinc Meets Bare Steel

Galvanized bolt and post-galvanizing tapped nut in assemblyA sectioned nut reveals bare steel internal threads mating with the zinc-coated bolt thread. Olive yellow identifies zinc; grey identifies steel.010203
01Sectioned nut02Zinc on the bolt03Bare nut thread meets zinc

The Contact: Zinc Protects the Steel

Sacrificial zinc protection at the thread contactThe bolt's zinc layer contacts bare nut steel on a thread flank. When moisture forms an electrolyte, zinc oxidizes preferentially. The green arrow follows the electrically connected metals to the nut steel, helping suppress steel corrosion.e⁻Zn²⁺010203
01Nut steel02Zinc-coated bolt03Metal contact at the flank
SteelZincMoisture / electrolyteElectrons through the metal

Principle diagram. Coating and clearances are enlarged; colours identify materials rather than actual finishes.

  1. 01

    Tapped After Galvanizing

    The nut blank is galvanized, then tapped to its specified thread tolerance. This leaves bare steel on the internal thread as a normal part of the process.

  2. 02

    Connected in Assembly

    The bolt’s zinc coating contacts the mating nut thread. This metal-to-metal contact creates the electrical connection needed for protection.

  3. 03

    Zinc Corrodes Preferentially

    In the presence of moisture acting as an electrolyte, zinc oxidizes more readily than steel, providing cathodic protection to adjacent exposed steel. Zinc acts as the sacrificial anode.

One Protection Principle. Both Assembly Routes.

ISO-fitting bolts with H / G standard internal-thread nuts, and conventional galvanized bolts with oversize-tapped nuts, can both benefit from this protection when correctly matched with nuts tapped after galvanizing and assembled. We supply both routes.

The Details Behind the Standard.

Compare product forms and the details to specify. ISO and DIN references identify requirements; dimensions and editions are confirmed with your quotation.

Before You Specify.

What do ISO-fit and ISO metric fitting thread mean?

These catalogue terms describe the intended fit with standard ISO metric internal threads. For this hot-dip galvanized route, ISO 965-4 defines the 6az external thread before coating. Specify the applicable standards, mating thread and inspection requirements when ordering.

Which ISO-fit bolt grades can you supply?

8.8U is our core range. We also supply 4.8U, 6.8U and 10.9U ISO-fit hot-dip galvanized bolts. Specify the required property class, dimensions, coating and inspection requirements with your enquiry so we can confirm the configuration for your order.

What does U mean in 4.8U, 6.8U, 8.8U and 10.9U?

The numbers identify the property class. Under ISO 10684, the additional U identifies threads made undersize before galvanizing. This thread allowance is the defining distinction of the ISO-fit route, allowing the coated bolt to mate with the specified standard internal thread. Confirm marking and acceptance requirements with your order specification.

Do I need to enlarge an existing tapped hole?

With the matching standard internal thread, no enlargement is needed to accommodate zinc on the bolt. The allowance is built into the external thread before galvanizing, helping retain existing tapped-hole dimensions.

Can ISO-fitting galvanized bolts replace stainless steel?

We offer cost-saving alternatives for suitable applications, particularly projects that retain existing standard tapped holes. Send the stainless steel bolt drawing, dimensions and quantity for a corresponding quotation and cost comparison. Material, property class and finish are recorded in the supply specification.

How are M6 process and inspection requirements specified?

M6 galvanizing, coated thread fit and mechanical testing are defined in a dedicated technical specification. ISO 10684 covers coarse-threaded steel fasteners from M8 to M64; the M6 process and acceptance criteria are agreed separately against the drawing.

Are oversize-tapped nuts or zinc electroplating unstandardized?

No. ISO 10684 and ISO 965-5 define hot-dip galvanized oversize internal-thread systems. Zinc electroplating is a different, standardized coating route covered by ISO 4042. The concern is uncontrolled enlargement or mismatched thread systems, not a properly specified alternative process.

Which nuts pair with ISO-fitting bolts?

ISO-fitting bolts pair with the specified H / G internal-thread nuts, commonly 6H. The matching galvanized nuts are tapped after coating, leaving their internal threads uncoated. Conventional HDG bolts use the specified oversize-tapped nuts. We supply both matched systems.

How are uncoated internal nut threads protected against corrosion?

Tapping a nut after galvanizing exposes steel on the internal thread. In the assembled joint, that steel contacts the zinc on the bolt. When moisture forms an electrolyte, zinc oxidizes preferentially and provides sacrificial, or cathodic, protection to the adjacent nut steel. This established mechanism applies to both matched hot-dip galvanized thread systems.

Do you also supply conventional HDG bolts with oversize-tapped nuts?

Yes. Alongside ISO-fitting bolts with standard nuts, we supply standard bolts that are hot-dip galvanized and paired with nuts tapped to the specified oversize tolerance. Send the drawing or product standard, dimensions, property class, coating and quantity for a matched quotation.

Is the zinc coating removed after galvanizing?

The intended route builds in thread allowance before galvanizing. Finished-thread acceptance should preserve the specified coating and follow the applicable product requirements.

What is checked after galvanizing?

Thread fit, coating thickness and mechanical properties are checked against the order specification. M8 and M10 undersized-thread bolts follow the applicable reduced-load requirements in ISO 10684.

Can I request a specific standard or coating thickness?

Yes. Include the standard, dimensions, thread requirements, coating thickness and inspection criteria with your enquiry. We confirm the configuration with the quotation.

What should I send for a quotation?

A drawing or standard, size and length, strength class, required finish, quantity and delivery country. Include any project-specific testing or documentation requirements.

Your Specification.
Our Next Conversation.

Send us your drawing, product list or project requirements. We’ll start with the details that matter.

Tell Us What You Need