Double-end studs have two threaded regions separated by a plain portion. DIN 939 identifies a form with a metal end of approximately 1.25 times the nominal diameter. One end enters a tapped component, while the other accepts the specified fastening arrangement. This makes the dimensions and fit of both ends important purchasing information.
Label the installation end and nut end on the drawing. Include their thread lengths, pitch and tolerance requirements, along with the unthreaded portion. A single diameter and nominal length can leave critical differences between two apparently similar studs unresolved at the quotation stage.
02
Check the Tapped Component
Provide the tapped-hole specification, available depth and material where these affect the joint. The 1.25d reference describes a standard geometry; it is not a universal recommendation for adequate engagement in every material. The assembly design determines the required engagement and installation fit.
03
Keep Finish and Fit Coordinated
Specify any coating allowance and acceptance criteria for both thread ends. If one end has a special fit or a surface restriction, identify it explicitly. For non-standard lengths or stepped forms, an approved drawing can define the requested configuration more clearly than the catalogue number alone.
FROM STANDARD TO ORDER
A Better Brief. A Clearer Quotation.
Send the dimensional standard or drawing together with material, finish and quantity. The quoted specification defines the product supplied.
Compare product forms and the details to specify. ISO and DIN references identify requirements; dimensions and editions are confirmed with your quotation.